REQUIREMENTS OF A PYROLYTIC MEDICAL WASTE BURNER FOR LARGE RANGE
1. Capacity of damage in weight: 500 kg/h.
2. It must have the ability to run not much less than 8 hours/day
3. This burner must be able to destruct all flammable wastes created by hospitals, private centers, laboratories, institutes, etc.
4. Design Spec: Kinds A, B, C, D, and also E of medical waste.
5. PYROLYTIC combustion, by controlling the gasification of waste.
6. The incinerator needs to prevent the release of black smoke and also fine dust, (Smokeless) during the loadings.
7. It must be able to reduce the volume of wastes by 98%.
8. It needs to have the ability to hold discharge in the 2nd melt with gas house of not much less than 2.
secs.
9. The incineration must be completely devoid of noticeable smoke as well as offensive smells.
10. The lower calorific power (L.C.P) of this waste will certainly be 3,500 kcal/kg.
The Temperature levels of combustion: Minimum will certainly be 850oC and also max 1400oC.
Article combustion: >> 1100oC.
11. The Internal diameter of the Smokeshaft: Ø 400 and also its height: 8 m.
12. The Volume of the burning chamber: 1.200 L.
13. The Measurement of the door for loading in cm: 120×× 120.
14. Burner procedure ought to be Automatic On/Off.
15. Fuel: diesel/Gas.
16. The supplier has to supply necessary details for the best of the installment This burner with PYROLYTIC burning need to have:.
17. A combustion chamber of waste:.
* Completely tight door for the hands-on loading of waste. The loading should be Handbook, Set.
Load.
* A heater of illumination which the use is limited to the ignition of waste.
* Frontage of packing with door seals risen on hinges, wheel of screw plug, versatile joint, as well as packing insulating out of refractory.
* The insulation of the combustion chamber should be made up of refractory blocks, having a high material of aluminium as well as protects bricks in order to assure a minimum temperature on.
the outside sheet metal.
* Make-up of the refractory;.
Refractory concrete:
. Density: 100 mm
. Nature: 42% of Al203.
Shield in coarse panels:
. Thickness: 75 mm.
Nature: Calcium silicate.
* Burner of illumination of waste, with fuel, conventional mono-bloc casting leading diving flame, lighting and safety and security of electronic ignition, long-term air flow, electro-magnetic sluice entrance of guideline and also isolating valve.
* Plate of combustion in Carborundum, avoiding the fixing of glass as well as slags.
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]